Transducers, Converters, Amplifiers & Monitors

002-500-123B Phase Monitor by Mpe inc.

MPE INC. PHASE MONITOR 10 A 240 VAC RESISTIVE 1/3 HP 240 VAC 1/6 HP 120 VAC 10 A 28 VDC CAT# 002-500-123B

10CS501 Transducer by Transdata

TRANSDATA TRANSDUCER INPUT 0-5 AMPS AC OUTPUT 0-1 MA DC CAT# 10CS501

118H-120-K-0-2 Temperature Monitor by Qualitrol

QUALITROL TRANSFORMER TEMPERATURE MONITOR 118H-120-K-0-2 WITH 0-1MA OUTPUT, CAT# 118H-120-K-0-2

1375-40 LFE Multiplier Assy

MULTIPLIER ASSEMBLY

1426-DM POWER MONITOR BY ALLEN-BRADLEY

ALLEN-BRADLEY, POWER MONITOR TOUCH DISPLAY, CAT# 1426-DM

1426-M5E POWER MONITOR BY ALLEN-BRADLEY

ALLEN-BRADLEY, POWER MONITOR 5000 BASIC MODULE, SERIES B, CAT# 1426-M5E

15171750234 Misc. Components and Parts

CALIBRATION: 5A, CURRENT TRANSDUCER

246953-540-AHD-0-0-JVW Transducer

Transducer, Input Type: 120V AC/5AMP AC, Input Calib. Freq. 60Hz, Output: 4-20MA DC, 0.5% of Span, 900 Watts, Cat# 246953-540-AHD-0-0-JVW

2475 WATT TRANSDUCER BY YOKOGAWA

YOKOGAWA WATT TRANSDUCER 3 PHASE 4 WIRE MODEL 2475 CAT# 2475

248922-33Q-AHD-1 Yokogowa Power Transducer

AC POWER SERIES POWER TRANSDUCER AC VOLTAGE INPUT TYPE 0-150V AC INPUT CALIBRATION FREQUENCY 60HZ OUTPUT 4-20MA DC 0.2% OF SPAN AUX POWER 120V AC

248931-380-AHD-1-JA0 Yokogowa Current Transducer

AC CURRENT TRANSDUCER AUX POWER 120V AC INPUT CALIBRATION FREQ. 60HZ OUTPUT 4-20MA DC (BRANDED YOKOGAWA)

248931-380-AHD-1/JA0

AC CURRENT TRANSDUCER AUX POWER 120V AC INPUT CALIBRATION FREQ. 60HZ OUTPUT 4-20MA DC (BRANDED YOKOGAWA)

253-TVLU-PQHG-C6-DG Transducer by Crompton

CROMPTON INSTRUMENTS CURRENT AND VOLTAGE TRANSDUCER INPUT: 120 VAC FREQUENCY 60 HERTZ OUTPUT 4-20 A INTO 500 OHMS AUXILIARY 120 V 60 HZ CAT# 253-TVLU-PQHG-C6-DG STYLE# 253-TVLU

256-TTMU Crompton Transducer

CROMPTON TRANSDUCER INPUT 0/50 MILLIVOLTS DC OUTPUT 4/20 MA INTO 500 OHMS AUXILIARY 125 V DC CAT# 356-TTMU

256-TWKU-QQHG-C6-WF Power Transducer by Crompton

CROMPTON TRANSDUCER 120 V L/N VT 480/120 5.2 A CT 50/5 RANGE 0/25 KILOWATTS CAT# 256-TWKU-QQHG-C6-WF

256-TWMU Transducer by Crompton

CROMPTON PALADIN WATT TRANSDUCER 3 PHASE 3 WIRE UNBALANCED LOADINPUT 120 VAC CPT 1200:120 INPUT 2.40 CT 100:5 RANGE 0-1000 KW FREQUENCY 60 HZ OUTPUT 0/1 mA CAT# 256-TWMU

256-TWNU Amp Meter by Crompton

CROMPTON 3-PHASE 4-WIRE UNBALANCED LOAD WATT TRANSDUCER INPUT 120 V L-N PT 288:120 2.89 CT 4000:5 RANGE 0-2 MEGA WATTS FREQUENCY 60 HZ OUTPUT 0/1 MA INTO 10 KOHMS CLASS INDEX 0.5% CAT# 256-TWNU

25EWS501 Transducer by Transdata

TRANSDATA WATT TRANSDUCER 3 PHASE 4 WIRE 2 1/2 ELEMENT 5 AMP 120 VOLT 60 HZ CALIBRATION 500 WATTS/ ELEMENT= 1 MA D.C. INTO 0 TO 10K CAT# 25EWS501

260D35G11 Current Monitor by Eaton, Cutler-Hammer or Westinghouse

Westinghouse, Current Monitor, 2000Amp 600VAC, Cat# 260D35G11

30EWM517E Watt Transducer by Transdata

TRANSDATA WATT TRANSDUCER 3 PHASE 4 WIRE 3 ELEMENT 5 AMPS 120 VAC 60 HZ CALIBRATION 600 WATTS/ELEMENT CAT# 30EWM517E

30EWS501AA WATT TRANSDUCER BY TRANSDATA

TRANSDATA, WATT TRANSDUCER, 3 PHASE, 4 WIRE, 3 ELEMENT, 5 AMP, 69V, 60HZ, CALIBRATION: 345 WATTS/ELEMENT=1MA D.C. INTO 0 TO 10K, CAT# 30EWS501AA

30WS101 Transducer by Transdata

TRANSDATA TRANSDUCER 120 VOLTS 5 AMPS 50-62 HZ CAT# 30WS101

320/CM2150 POWERLOGIC CIRCUIT MONITOR BY SQUARE D

SQUARE D, POWERLOGIC CIRCUIT MONITOR, TYPE 1, CAT# 320/CM2150

3567 E Scientific Transducer

R M S VOLTAGE TRANSDUCER

3700-ACM-1-A-0-A DISPLAY POWER MONITOR BY POWER MEASUREMENT LTD

POWER MEASUREMENTS LTD, DISPLAY POWER MONITOR, POWER SUPPLY: 120 VAC/DC, 0.2 AMP, OUTPUT REL;AY: 120VOLTS, 40/60HZ, 1 AMP RESISTIVE, VOLTAGE SENSE INPUTS: 120 VOLTS TO GROUND MAX, CURRENT SENSE INPUTSf: 5 AMPS, 7 VOLTS TO GROUND MAX, CAT# 3700-ACM-1-A-0-1

3700-ACM-1-B-0-B DISPLAY POWER MONITOR BY POWER MEASUREMENTS LTD

POWER MEASUREMENT LTD, DISPLAY POWER MONITOR, POWER SUPPLY: 120 VAC/DC, 0.2 AMP, OUTPUT RELAY: 120 VOLTS, 50/60HZ, 1 AMP RESISTIVE, VOLTAGE SENSE INPUTS: 120 VOLTS TO GROUND MAX, CURRENT SENSE INPUTS: 5 AMPS, 7 VOLTS TO GROUND MAX, CAT# 3700-ACM-1-B-0-B

4074A E Scientific Transducer

R M S CURRENT TRANDUCER

43265 Esterline Isolation Amplifier

DC ISOLATION AMPLIFIER MODEL 6271A

47VA32H Voltage Monitor by Furnas

VOLTAGE MONITOR SERIES B 480 VOLTS AC, 60 HERTZ SUPPLY FUSE ALL LINES WITH 1 AMP FUSES

6271P-AN6-Z Esterline Isolation Transducer

PROCESS CONTROL DC ISOLATION TRANSDUCER, CALIBRATION IS 0 - 10 VDC, INPUT CORRESPONDS TO 0- 5 mA output into 0 - 3 K ohm load

781P6 Transducer by Moore

MOORE P/E TRANSDUCER B/M 15007-2S1 INPUT 3-15 PSI OUTPUT 4-20 MA CAT# 781P6

7MH71450A by Siemens

SIEMENS MILLTRONICS REMOTE MOUNTED PRE-AMPLIFIER INPUT 0 TO 1 V OUTPUT 12 MA LOW 45 MA HIGH SUPPLY 24 V DC FROM ASSOCIATED MAIN AMP CAT# 7MH71450A

7ML11000BA20 Transducer by Siemens

SIEMENS TRANSDUCER STH. 2 IN. NPT 10 M FM CAT# 7ML11000BA20

8272-711 by Woodward

WOODWARD ISOLATED SIGNAL CONVERTER 10-40 VDC SUPPLY 3 WATT INPUT CAT# 8272-711

870022-012-11-00-01-27-00 Transducer by Honeywell

HONEYWELL ELECTRO-PNEUMATIC TRANSDUCER CLASS 1 GROUP D RANGE 4-20 MA D.C. CAT# 870022-012-11-00-01-27-00

908 Current Sensor by Veris Industries

VERIS INDUSTRIES HAWKEYE 908 ADJUSTABLE SPLIT-CORE CURRENT SENSOR OUTPUT 0.5 A @ 30 VAC/DC MAXIMUM SENSED AMPEREAGE 200 A CAT# 908

AT2A-5 Transducer by Crompton

Crompton, Paladin AT2 series Transducer, Input 5 Amps AC~

AVT-150C Transducer by Flex-Core

FLEX-CORE TRANSDUCER INPUT: 0-150 VAC 50/60 HZ CALIBRATION 0-150 VAC= 0-10 VDC OUTPUT CAT# AVT-150C

B9017BX WATT TRANSDUCER BY YOKOGAWA

YOKOGAWA, WATT TRANSDUCER, AC POWER SERIES, INPUT TYPE 120VAC/5 AMP, INPUT CALIB 60HZ, OUTPUT 4-20MA DC, 676.34 WATTS, STYLE# 246953-540-AHD-0-0/JCJ, CAT# B9017BX

C5-E1-XA-F60-Z0-A1-G0 Current Transducer by RIS

RIS CCC-1B CURRENT TRANSDUCER INPUT 5, POWER SUPPLY 85-150, OUTPUT 4-20, FREQUENCY 60 HZ, CALIBRATION STANDARD, ACCURACY +-0.5%, CASE GROUND TERMINAL NONE CAT# C5-E1-XA-F60-Z0-A1-G0

CCC-1B Transducer by Rochester Instrument

CURRENT TRANSDUCER INPUT, AC AMPS: C1=1, C2=2, C5=5, C10=10, C15=15, C20=20, C25=25 POWER SUPPL VOLTS: E0= self powered, E1=85-150, E2- 170-300, E3= 300-550, E4= 50-90 HERTZ: F50=50, F60=60, F400=400 CALIBRATION: Z0= standard ACCURACY: A1= +or- 0.5%, A2= =or- 0.25%, A3=+or- 0.1%

CCE-A Transducer by Circutor

CIRCUTOR TRANSDUCER 110 VCA CURRENT 5 A CAT #CCE-A

CLE-201031 Voltage Transducer by Square D Company

Square D Company, Voltage Transducer, Input: 0-150V AC, Output: 0-1mA DC, Cat# CLE-201031

CLE-202001 Current Transducer by Square D Company

Square D, Current Transducer, Input: 3-4 0-5A AC, Output: 1-2 0-1AA DC, Cat# CLE-202001

CLE-202031 Transducer by Square D

Square D, Current Transducer, Input: 0-5A AC, Output: 0-1mA DC, Cat# CLE-202031

CLE-204002S Transducer by Square D

SQUARE D WATT TRANSDUCER 2 ELEM 3 PHASE 3 WIRE 120 VOLT 5 AMP 60 HZ INPUT 1 mADC INTO 0-10 K OHM AT 1000 WATTS OUTPUT CAT# CLE-204002S

CLE-207100 Amplifier by Square D

SQUARE D PROCESS SIGNAL AMPLIFIER CLASS 8410 CAT# CLE-207100

CLM-420 Current Loop Converter by EIL

E I L CURRENT LOOP CONVERTER INPUT 0-25 MVDC OUTPUT 4-20 MADC CAT# CLM-420

COM-128-1 Converter by Power Measurement

POWER MEASUREMENT MULTIPORTS-232C TO RS-485 CONVERTER SPECIFICATIONS: BAUD RATE: 1200 TO 19200 BAUD, ISOLATION: 750 VOLTS BETWEEN RS-485 AND RS-232C, RS-232 TO FOUR RS-485 PARTS AND MODEM CONTROL SIGNALS, SUPPORT 128 DEVICES WITH 120 VAC STANDARD POWER SUPPLY CAT# COM-128-1

CT-510-A2 Transducer by Scientific Columbus

EXCLTRONIC CURRENT TRANSDUCER INPUT: 0-5 AMP AC OUTPUT: 0-10 MA DC CAT# CT-510-A2

CT-510P-A7 Current Transducer by Scientific Columbus

Scientific Columbus, Process Control Current Transducer, Input: 0-5Amp, Output: 4-20mA, 0-2000 Ohms Load, Cat# CT-510P-A7