Relaying
12IFC66K1A Overcurrent Relay by General Electric
LONG TIME OVERCURRENT RELAY 60 HERTZ INSTANTANEOUS UNIT: 6-150 HIGH DROP OUT: 2-8 AMPERES INSTRUCTIONS: GEK- 45376 PARTS BULLETIN: GEF-4533 INCLUDES CASE
12IFC66KD1A Overcurrent Relay by General Electric
LONG TIME OVERCURRENT RELAY 60 HERTZ INSTANTANEOUS UNIT: 6-150 HIGH DROP OUT: 2-8 AMPERES INSTRUCTIONS: GEK-49949 PARTS BULLETIN: GEF-4533 INCLUDES CASE
12IJCV51A1A Relay by General Electric
General Electric Relay Overcurrent Relay with Voltage Resistant, 115 Volts, Pick-Up Range 1-4 Amp, 0 volts, 4-15 Amp, 115 Volts CAT # 12IJCV51A1A
12IRT51F1A Temperature Relay by General Electric
TEMPERATURE RELAY TYPE IRT FOR USE WITH 10 OHMS @ 25 DEGREES C RTD: COPPER OPERATING RATING: 120-240 VOLTS 50/60 HERTZ AUXILIARY CIRCUIT: 120-240 VOLTS 50/60 HERTZ, 125-250 VOLTS DC INSTRUCTIONS: GEK-36038 PARTS BULLETIN: GEF-4046 INCLUDES CASE
12NAA15E6A Auxillary Relay by General Electric
TRANSFER TRIP AUXILIARY RELAY TYPE NAA 48/125/250 VOLTS DC O.C.UNIT 3 A. 50/60 HERTZ CAL.1/1.6/2.5/4 INSTRUCTIONS: GEI-98340 INCLUDES CASE
12NGA15X2 RELAY BY GENERAL ELECTRIC
GENERAL ELECTRIC RELAY 125VDC CAT#12NGA15X2
12NGV13A11A UNDERVOLTAGE RELAY BY GENERAL ELECTRIC
GENERAL ELECTRIC UNDERVOLTAGE RELAY 120 VOLTS 60 HZ DROP OUT 70-100 VOLTS TYPE NGV CAT# 12NGV13A11A ****INCLUDES CASE****
12NGV13B30A UNDER VOLTAGE RELAY BY GENERAL ELECTRIC
GENERAL ELECTRIC AC UNDERVOLTAGE RELAY 120 VOLTS 50/60 HZ DROPOUT CALIBRATION 60-120 V TARGET AMPS 0.2 CAT# 12NGV13B30A
12NLR11A2A Reclosing Relay by General Electric
RECLOSING RELAY TYPE: NLR VOLTS: 125 HERTZ: DC STEP TIME 5 SECONDS UNLESS OTHERWISE SPECIFIED RECLOSING TIME = CAM SETTING X STEP TIME TOTAL RECLOSING CYCLES = 36 X STEP TIME INSTRUCTIONS: SFR-26747 INCLUDES CASE
12NLR11C3A Reclosing Relay by General Electric
RECLOSING RELAY TYPE NLR 48/125 VOLTS DC STEP TIME 5 SECONDS UNLESS OTHERWISE SPECIFIED RECLOSING TIME = CAM SETTING X STEP TIME TOTAL RECLOSING TIME = 36 X STEP TIME INSTRUCTIONS: GEK-6851 INCLUDES CASE
12NSR21H1A RELAY BY GENERAL ELECTRIC
GENERAL ELECTRIC, NSR RECLOSING RELAY, SECONDS CALIBRATION .05/.1/.3/1/2/3, 24/48/125 VOLTS, RESET TIME: 3-20, RECLOSING TIME .05-3, CAT# 12NSR21H1A
12PJC11A2 Current Relay by General Electric
INSTANTANEOUS CURRENT RELAY TYPE PJC OPERATING COIL 3 AMP A-C/DC TARGET HOLDING COILAMP INSTRUCTIONS: GEI-12090 PB INCLUDES COVER
12PJC11A4 Relay by General Electric
INSTANTANEOUS CURRENT RELAY TYPE: PJC OPERATING COIL: 12 AMPS HERTZ DC: 25, 60 INSTRUCTIONS: GEH-1790 INCLUDES CASE
12PJC11AV3A Relay by General Electric
General Electric Relay Instantaneous Current Relay, Oper Coil 1.5 Amp, DC/25/60, Target-Holding Coil Amp CAT # 12PJC11AV3A
12PJC11B1 Current Relay by General Electric
INSTANTANEOUS CURRENT RELAY TYPE PJC AMPS: 10 RANGE DC: 4/100 HERTZ: 25/60 INSTRUCTIONS: GEH-1790 INCLUDES COVER
12PJC12D3A CURRENT RELAY BY GENERAL ELECTRIC
GENERAL ELECTRIC INSTANTANEOUS CURRENT RELAY TYPE PCJ OPERATING COIL 6 AMPS DC 25/60 HZ CAT# 12PJC12D3A *DOES NOT INCLUDE CASE*
12PJC14D3 Relay by General Electric
INSTANTANEOUS CURRENT RELAY TYPE: PJC OPERATING COIL: 6 AMPS HERTZ DC: 25, 60 INSTRUCTIONS: GEH-1790 INCLUDES CASE
12PJC14D4 Relay by General Electric
INSTANTANEOUS CURRENT RELAY TYPE: PJC OPERATING COIL: 12 AMPS HERTZ DC: 25,60 INSTRUCTIONS:GEH-1790 INCLUDES CASE
12PJG11F7A MACHINE FIELD GROUND DETECTOR BY GENERAL ELECTRIC
GENERAL ELECTRIC MACHINE FIELD GROUND DETECTOR 120-240 VOLTS 25 HZ TYPE PJG *DOES NOT INCLUDE CASE* CAT# 12PJG11F7A
12PJV11A1 Overvoltage Relay by General Electric
INSTANTANEOUS OVERVOLTAGE RELAY TYPE PJV OPERATING COIL 115 VOLTS 60 HERTZ INSTRUCTIONS: GEI-30971 INCLUDES COVER
12PJV11A19 Relay by General Electric
INSTANTANEOUS VOLTAGE RELAY TYPE: PJV OPERATING COIL: 67 VOLTS HERTZ: 60 INSTRUCTIONS: GEI-30971 INCLUDES CASE
12SAM11B22A RELAY BY GENERAL ELECTRIC
GENERAL ELECTRIC RELAY 48/125/250VDC CAT#12SAM11B22A
12TMC11B1A Thermal Overcurrent Relay by General Electric
THERMAL OVERCURRENT RELAY TYPE TMC COIL RATING: 2.42 AMPERES 50/60 HERTZ INSTANTANEOUS UNIT: 10/40 AMPERES INSTRUCTIONS: GEI-44203 INCLUDES CASE
12XCA28A1 General Electric Meter Test Plug
METER TEST PLUG / BLOCK
12XLA12A1 Relay Test Plug by General Electric
General Electric, Relay Connection, Cat# 12XLA12A1
1338986-A Relay by Eaton, Cutler Hammer or Westinghouse
WESTINGHOUSE INVERSE OVERCURRENT RELAY, RANGE- 4-15A, CAT # 1338986-A
1339370-A Duplex Time Relay by Eaton, Cutler Hammer or Westinghouse
DUPLEX TIME DELAY RELAY TYPE: TH VOLTS: 120 HERTZ: 60 MIN. DELAY APPROX. 15 SECONDS MAX. DELAY APPROX. 60 SECONDS INCLUDES CASE
1340011003 Ammeter
AC AMMETER 0-25 INPUT= 0.20MA AC
1342925E AUXILIARY RELAY BY ABB
ABB, SG AUXILIARY RELAY, 125VDC, INCLUDES OUTER CASE, CAT# 1342925E
1342929.0 Auxiliary Relay by ABB
ABB, Auxiliary Relay, Type SG 115V 50/60Hz, Cat# 1342929.0
1343037 Relay by Eaton, Cutler Hammer or Westinghouse
WESTINGHOUSE TYPE MG-6 AUXILIARY RELAY, 125 VDC, STYLE # 1343037
1343D13 Aux Relay by Eaton, Cutler-Hammer or Westinghouse
AUXILIARY RELAY TYPE MG-6 HERTZ: 60 VOLTS: 230 INCLUDES CASE
1343F56A45 Relay by Eaton, Cutler Hammer, or Westinghouse
STATIC OUTPUT RELAY TYPE: SRU CONTROL VOLTS: 125 DC TRIP CIRCUIT VOLTS: 125 DC SCHEMATIC: 1333D60 INSTRUCTIONS: 41-846.1 INCLUDES PRINTED CIRCUIT BOARDS
1351D17A04 Relay by Eaton, Cutler Hammer or Westinghouse
WESTINGHOUSE, TYPE IT RELAY, INDICATOR 0.2-2 AMPS, INSTANTANEOUS TRIP .5-1.0 AMPS, 9640A39 CAT # 1351D17A04
1351D18A01 RELAY BY EATON, CUTLER HAMMER OR WESTINGHOUSE
WESTINGHOUSE IT TYPE RELAY 0.2 AMPS CAT# 1351D18A01
1355D27A04 Relay by ABB
MRC RECLOSING RELAY 48 VOLTS DC 125 VOLTS DC 120 VOLTS AC 50/60 HERTZ SCHEMATIC: 1355D46 ILL.: 41-865 DOES NOT INCLUDE PULL-OUTS or CASE
1356D35A01 Relay by ABB
ABB, CVX-1 Synchro-Verifier Relay, Voltage Unit 120 Volts 60Hz Indicator .2-2 Amps, Cat# 1356D35A01
1400-PD51A Allen Bradley Power Monitor Display
POWER MONITOR DISPLAY & BLOCK POWER SUPPLY 85-264 AC OR .10-300VDC CURRENT INPUT 5A FULL SCALE VOLT INPUT 120V LINE-NEUTRAL 208V LINE-LINE
1419342 Relay by Eaton, Cutler-Hammer or Westinghouse
Westinghouse, Relay, Coil: 250VDC 14V Holds, Style# ASR-11S, Cat# 1419342
1482105-C or 1482105C Relay by Eaton, Cutler Hammer or Westinghouse
WESTINGHOUSE TYPE XT7, AUTOMATIC SYNCHRONIZER, 115 VOLTS, 60 Hz, CAT # 1482105-C or 1482105C
14C217 Relay by Omron
OMRON REVERSING CONTACTOR KIT 1/4-3 HP 24 VDC CAT# 14C217
1529F93A05 B Relay by Eaton, Cutler-Hammer or Westinghouse
EATON, CUTLER-HAMMER OR WESTINGHOUSE RELAY CAT# 1529F93A05 B
1532F87A02 Relay by Eaton, Cutler Hammer, or Westinghouse
RELAY TYPE: SKBU-2A VOLTS DC: 48 TYPE CHANNEL: TCF.MC-22 TA2.2 PHASE COMPARISION INSTRUCTIONS: 41-954.6 INCLUDES PRINTED CIRCUIT BOARDS
1543878 Overcurrent Relay by Eaton, Cutler-Hammer or Westinghouse
OVERCURRENT RELAY TYPE C0-10 EXTREMELY INVERSE TIME HERTZ: 60 OVERCURRENT ELEMENT: 4-12 AMPS CONTACTS: SPST INSTANTANEOUS TRIP: 20-80 AMPS CONTACTS: SEP. INDICATOR COIL: 1 AMP CONTACTOR SWITCH: 2 AMPS INCLUDES CASE
1545012 Relay by Eaton, Cutler Hammer or Westinghouse
ADJUSTABLE INVERSE TIME OVERCURRENT RELAY TYPE CO AMPS: 0.5-2.5 HERTZ: 60 INDICATOR: 0.2 AMPS STYLE CA.: 115259-E INCLUDES CASE
1545065-A Relay by Eaton, Cutler-Hammer or Westinghouse
EATON, CUTLER-HAMMER OR WESTINGHOUSE 4-12AMPS 60 CYCLES TYPE CO CAT# 1545065-A
1545066-A OVERCURRENT RELAY BY EATON, CUTLER HAMMER OR WESTINGHOUSE
WESTINGHOUSE ADJUSTABLE INVERSE TIME OVERCURRENT RELAY 4-12 AMPS 60 HZ TYPE C0 ****INCLUDES CASE**** CAT# 1545066-A
1545383 AC Volt Meter by Eaton, Cutler Hammer or Westinghouse
AC VOLTS METER TYPE:KA24 RANGE: 0-600 FULL SCALE: 1550 VOLTS AC USE WITH PT RATIO 4/1
1546537 Meter by Eaton, Cutler Hammer, or Westinghouse
Westinghouse, A-C Amperes Meter, Type KA-24, F.S.=5 Amp, 60Hz, Cat# 1546537
16-Y-8512-1 Overcurrent Relay by Eaton, Cutler Hammer or Westinghouse
OVERCURRENT RELAY TYPE: C0 OVERCURRENT ELEMENT: 2-6 AMPS CONTACTS: SPST INDICATOR COILS: 1 AMP CONTACTOR SWITCH: 2 AMPS INSTANTANEOUS TRIP: 4-16 AMPS CONTACTS: SEP. VERY INVERSE TIME INCLUDES CASE
162141LSRL Meter Master Ammeter
AC AMMETER 0-200