Transducers/Converters/Amplifiers/Monitors
Fairchild
TRANSDUCER SERVICE KIT MODEL T5221, 12132
Esterline
DC ISOLATION AMPLIFIER MODEL 6271A
Yokogowa
AC POWER SERIES POWER TRANSDUCER AC VOLTAGE INPUT TYPE 0-150V AC INPUT CALIBRATION FREQUENCY 60HZ OUTPUT 4-20MA DC 0.2% OF SPAN AUX POWER 120V AC
Yokogowa
AC CURRENT TRANSDUCER AUX POWER 120V AC INPUT CALIBRATION FREQ. 60HZ OUTPUT 4-20MA DC (BRANDED YOKOGAWA)
Esterline
PROCESS CONTROL DC ISOLATION TRANSDUCER, CALIBRATION IS 0 - 10 VDC, INPUT CORRESPONDS TO 0- 5 mA output into 0 - 3 K ohm load
Spang Power Control
TRANSDUCER TYPE DCCT2 VOLTS: 120 HERTZ: 60 CURRENT RATIO 4000:1 MAX. BUS: 200 AMPS MAX. AMBIENT: 55 DEGREES C ACCURACY: 1% FS MAX. BURDEN: 1000 OHMS
Rochester Instrument
CURRENT TRANSDUCER INPUT, AC AMPS: C1=1, C2=2, C5=5, C10=10, C15=15, C20=20, C25=25 POWER SUPPL VOLTS: E0= self powered, E1=85-150, E2- 170-300, E3= 300-550, E4= 50-90 HERTZ: F50=50, F60=60, F400=400 CALIBRATION: Z0= standard ACCURACY: A1= More...
EIL Instruments
WATT TRANSDUCER 3 PHASE 3 WIRE 2 ELEMENT INPUT: 5 AMPS AC VOLTS: 120 VAC CALIBRATION: 500 WATTS/ELEMENT
E Scientific
PROCESS CONTROL TRANSDUCER 3 PHASE 3 WIRE 2 ELEMENT CALIBRATION: 0-1000 WATT INPUT: CORRESPONDS TO 4-20 mA OUTPUT: INTO 0-750 OHMS NOMINAL INPUTS: 5 AMPS 120 VOLTS 60 HERTZ
E Scientific
PROCESS CONTROL P.F. TRANSDUCER CALIBRATION: .5-0-.5 PF INPUT: COMPRESSED TO 4-12-20 mA OUTPUT: INTO 0-750 OHMS NOMINAL INPUTS: 5 AMPS 120 VOLTS 60 HERTZ
Siemens
9230 ACCESS POWER MODULE INCLUDES BACK MODULE P/N DSP3-G-115A MAX. VOLTAGE; 300V L-N, 600V L-L MAX. CURRENT: 10 AMPS FREQ.: 45-75 HERTZ POWER INPUT: 115VAC+/- 20%10VA INCLUDES COMMUNICATION CONVERTER P/N SF485DB3
Furnas
VOLTAGE MONITOR SERIES B 480 VOLTS AC, 60 HERTZ SUPPLY FUSE ALL LINES WITH 1 AMP FUSES
Eaton, Cutler Hammer or Westinghouse
SYSTEM VOLTAGE MONITOR PROTECTIVE RELAY FOR 3 PHASE, WYE, DELTA CONNECTED, 3 WIRE, POWER DISTRIBUTION NETWORKS VOLTAGE: 380/440 HERTZ: 50/60 MFG. CODE: ETIEG CONTACT RATING: 120/240 VOLTS AC 2750 VA BREAK RATING: 120/240 VOLTS AC 275 VA SAME More...
Eaton, Cutler Hammer or Westinghouse
POWER CONVERSION EQUIPMENT SVX 9000 INPUT 1:380-500V 50/60 HERTZ OUTPUT 2:3-0-VIN 0-500 HERTZ NEMATYPE 12
Eaton, Cutler Hammer or Westinghouse
POWER CONVERSION EQUIPMENT CAT#SVX007A1-4A1B1C2 INPUT V1:3-380-500V OUTPUT V2:3-0-VIN 0-500 HZ NEMA TYPE 1
Eaton, Cutler Hammer or Westinghouse
EATON CUTLER HAMMER POWER CONVERSION EQUIPMENT INPUTV1: 3-380-500 VOLTS OUTPUT V2:3-0-V1 0-320 HZ NEMA TYPE 1
Circutor
CIRCUTOR AC VOLTAGE TRANSDUCER MEASURING INPUT VOLTAGE RANGE 0-500V FREQUENCY RANGE 45-65 HZ
Circutor
CIRCUTOR TRANSDUCER 110 VCA CURRENT 5 A CAT #CCE-A
Crompton
CROMPTON TRANSDUCER INPUT 0/50 MILLIVOLTS DC OUTPUT 4/20 MA INTO 500 OHMS AUXILIARY 125 V DC CAT# 356-TTMU
Siemens
SIEMENS MILLTRONICS REMOTE MOUNTED PRE-AMPLIFIER INPUT 0 TO 1 V OUTPUT 12 MA LOW 45 MA HIGH SUPPLY 24 V DC FROM ASSOCIATED MAIN AMP CAT# 7MH71450A
Belloform
BELLOFRAM I/P TRANSDUCER INPUT 4-20 MA OUTPUT 3-15 PSI SUPPLY 25 PSIG CAT# TYPE 1000
Veris Industries
VERIS INDUSTRIES HAWKEYE 908 ADJUSTABLE SPLIT-CORE CURRENT SENSOR OUTPUT 0.5 A @ 30 VAC/DC MAXIMUM SENSED AMPEREAGE 200 A CAT# 908
EIL Instruments
E I L CURRENT LOOP CONVERTER INPUT 0-25 MVDC OUTPUT 4-20 MADC CAT# CLM-420
Red Lion
RED LION CONTROLS PULSE RATE TO ANALOG CONVERTER MODEL PRA1 AC POWER 115 VAC 50/60 HZ OUTPUT CURRENT RANGE 4-20 MA CAT# PRA1-1021
Moore
MOORE P/E TRANSDUCER B/M 15007-2S1 INPUT 3-15 PSI OUTPUT 4-20 MA CAT# 781P6
Honeywell
HONEYWELL ELECTRO-PNEUMATIC TRANSDUCER CLASS 1 GROUP D RANGE 4-20 MA D.C. CAT# 870022-012-11-00-01-27-00
Eaton, Cutler Hammer or Westinghouse
EATON TRANSDUCER ONLY 50 HZ 5 A 90-265 V AC/DC NO DISPLAY CAT# IQ260TA55100 STYLE# 65A2039G03
Eaton, Cutler Hammer or Westinghouse
EATON CURRENT TRANSDUCER 1600 A 0.333 V SPLIT CORE CAT# IQ35M-SP-255-1600 STYLE# 65C2004G04